• Cold Draw Guide Rail T70/a
  • Cold Draw Guide Rail T70/a
  • Cold Draw Guide Rail T70/a
  • Cold Draw Guide Rail T70/a
  • Cold Draw Guide Rail T70/a
  • Cold Draw Guide Rail T70/a

Cold Draw Guide Rail T70/a

Type: Safety System
Load Capacity: 1000kg
Persons: <5
Speed: 1.00-2.00m/s
Drive Mode: AC
Control Type: Microcomputer Control
Customization:
Manufacturer/Factory, Trading Company
Gold Member Since 2018

Suppliers with verified business licenses

Jiangsu, China

Basic Info.

Model NO.
T70/A
Lift Mechanism
Telescoping Lift
Use of Occasions
Public Traffic
Guide Rail
T Guide
Standard
ISO7465
Length
5m
Name
Elevator Guide Rail
Shape
T Type Rail
Raw Material
Q235
Transport Package
Be Packed in Export-Applicable Tray
Specification
ISO7465
Trademark
Xinxing
Origin
China
HS Code
8431310090

Product Description

Product Description

We provide T70 elevator guide rails by international standard with high quality and competitive price. If you are interested in this type of elevator guide rail, please feel free to contact me.

Information  of  T type elevator guide rails T70:
 
We have two kinds T70.T70-1/B is machined guide rail,T70/A is cold draw guide rail.Machined guide rail is much cheaper than cold draw guide rail.Their sizes are almost same,please refer to the drawing.


 
1.  basic dimensions: 70mm*65mm*9mm
notes: bottom width is 70mm, height is 65mm, top width is 9mm, length is 5meters.
2.  basic dimensions of its matched accessories
fishplate: 250mm*70mm*10mm; clip:8k; screw:M12*35
3.  processing methods:  machining or cold-drawing
4.  a 20` container can hold about 600 pcs of T70 elevator guide rails without accessories.

 
5.   material: all T  types of guide rails material is Q235
Item    Grade  Chemical Composition
C Mn Si S P
Q235 0.14-0.22 0.35-0.65 0.12-0.30 ≤0.05 ≤0.045
Mechanical property  
 Yield Strength N/mm2 Tensile Strength N/mm2 Elongation  
≥235 400-450 ≥24  



Cold draw guide rail 
T45/A:45mm*45mm*5mm;       T50/A 50mm*50mm*5mm      ; T70/A: 70mm*65mm*9mm
 
Machined guide rail:
T70-1/B : 70mm*65mm*9mm
T75/B orT75-3/B: 75mm*62mm*10mm
T78/B: 78mm*56mm*10mm

T82/B: 82.5mm*68.25mm*9mm
T82-3/B:82mm*62mm*15.88mm
T89/B or T89-1/B:  89mm*62mm*16mm
T90/B: 90mm*75mm*16mm
T114/B:114mm*89mm*16mm
T127-1/B: 127mm*89mm*16mm
T127-2/B: 127mm*89mm*16mm
 
 
Cold Draw Guide Rail T70/a

Hollow guide rail:
TK5A(TH5A) ;TK5(TH5);TK3A(TH3A)
Cold Draw Guide Rail T70/a

 
Remarks
All our products are produced according to ISO7465 international standard. If you have your own standard, we can also produce according to your specific dimensions. Dimensions displayed here is only a brief version. If you want details, please contact us. 

Package

Cold Draw Guide Rail T70/a




About Us

With more than 30 years' experience in machinery industry, Mr.Qian has the factory of his own in 2001.
Since 2006, our factory has developed from a factory that mainly provides machinery processing services to a specialized manufacturer of a series of guide rails for elevators. These elevator guide rails are usually used for vertical lifts & elevators to slide up and down safely and smoothly.
Our factory has passed ISO 9001 certificate. And our guide rails has passed type test in our industry.
      
Cold Draw Guide Rail T70/a

After several years in this field,now we also can supply some other elevator parts, if they exported with the rails ,the price will be much better. For more information please refer to our website


    

Cold Draw Guide Rail T70/a




 
Elevator Guide Rails - Frequently Asked Questions
 
How to name guide rails?
 The departure point of naming guide rails varies from country to country. Some name the guide rail according to the width of its aspect of guiding, such as T9, T16. While others name based on its weight, like 8LB, 12LB . However, we mostly name guide rail according to its width of bottom, for example: T70, T50.
 What difference is there between cold-drawn and planed guide rails? 
 The process for cold-drawn involves stretching the material thus modifying its structure. Planing involves machining the guide rail by stripping the edgings.
 Are the speed limits for the different qualities precise?
 No, the calculations for comfort are carried out using a mathematical model validated with practical tests, hence the speed limits set are approximate.
 Why are the guide rails 5 meters long?
 The guide rails are 5 meters long because it is the appropriate manufacturing length and allows the parameters for straightening to be checked properly.
 Do the guide rails have any surface treatment?
 No, the guide rails do not have surface treatments. On cold-drawn guide rails the cold-drawn process modifies the mechanical features of the material.

 

 


 
 
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2018

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Plant Area
>2000 square meters
Management System Certification
ISO 9001